The Anybus Modbus RTU to TCP gateway makes it possible to easily connect a RTU network to a TCP network. Alternative = Intesis Modbus Router INMBSRTR0320000.
Connect your CAN device to a Profinet network with the Anybus Communicator. The Communicator provides an intelligent conversion between the CAN protocol and the chosen industrial fieldbus network.
Integrate Modbus RTU devices in a Modbus TCP network with the Intesis Modbus Router INMBSRTR0320000. Up to 5 Modbus TCP clients and 32 Modbus RTU servers.
This gateway allows Modbus TCP/RTU devices to communicate on a BACnet IP & or MS/TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 100 points
Integrate OCPP 1.6-based electric vehicle charging stations with any Modbus RTU or TCP controller or connect the chargers to an external OCPP Central System (CS) and monitor them via Modbus.
The DALI /DALI2 to KNX gateway allows DALI devices to communicate on KNX network. The gateway works as a translator between the two networks. For 64 DALIdevices.
Connect your CAN device to a CANopen network with the Anybus Communicator. The Communicator provides an intelligent conversion between the CAN protocol and the chosen industrial fieldbus network.
Connect your CAN device to a Modbus-TCP network with the Anybus Communicator. The Communicator provides an intelligent conversion between the CAN protocol and the chosen industrial fieldbus network.
This DALI / Dali-2 to Modbus gateway allows DALI devices to communicate on a Modbus network. The gateway acts as a translator between the two networks. For up to 64 DALI devices.
This Modbus TCP & RTU server gateway allows Modbus devices to communicate on a Bacnet network. Up to 5 simultaneous Modbus TCP servers and up to 32 Modbus devices per RTU node (without repeater) and up to 255 in total. 100 data points.
Connect your Profinet slave device to EtherNet/IP via the new generation Universal Anybus Communicator ABC4013. This gateway performs intelligent protocol conversion and provides the slave data to the EtherNet/IP Master.
Connect your RS-232/485 device to Profibus via the new generation Universal Anybus Communicator ABC3000. This gateway performs intelligent protocol conversion and provides the serial data to the Profibus Master.
Protocol translator for the integration of AC units into building automation systems. Supports Hisense, Hitachi, Midea, Mitsubishi Electric, Panasonic and Samsung.
This gateway allows Modbus TCP/RTU devices to communicate on a BACnet IP & or MS/TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 3000 points
Connect your CAN device to a Profibus DPV1 network with the Anybus Communicator. The Communicator provides an intelligent conversion between the CAN protocol and the chosen industrial fieldbus network.