This BACnet IP & MS/TP client gateway connects KNX devices to a BACnet network. This makes the KNX data available in the BACnet network. Up to 250 nodes.
Connect your Modbus TCP network to Profibus DP via the new generation Universal Anybus Communicator ABC4018. This gateway performs intelligent protocol conversion and provides the Modbus data to the Profibus Master.
Anybus Communicator ABC3190 common Ethernet is a industrial protocol gateway to connect EtherCAT devices (slaves) to EtherNet/IP-, Modbus TCP-, en PROFINET networks.
This BACnet MS/TP or IP server gateway connects BACnet devices with an ASCII IP or serial controller. This makes the BACnet data available in the ASCII network. Up to 100 nodes.
This gateway allows Modbus TCP/RTU devices to communicate on a BACnet IP & or MS/TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 600 points
The BACnet IP & MS/TP to KNX gateway allows BACnet devices to communicate on a KNX TP network. The gateway works as a translator between the two networks. For 100 data points
Connect your CAN device to an EtherCAT network with the Anybus Communicator. The Communicator provides an intelligent conversion between the CAN protocol and the chosen industrial fieldbus network.
This Modbus TCP & RTU server gateway allows Modbus devices to communicate on a Bacnet network. Up to 5 simultaneous Modbus TCP servers and up to 32 Modbus devices per RTU node (without repeater) and up to 255 in total. 250 data points.
This DALI / Dali-2 to Modbus gateway allows DALI devices to communicate on a Modbus network. The gateway acts as a translator between the two networks. For up to 64 DALI devices.
This BACnet MS/TP or IP server gateway connects BACnet devices with an ASCII IP or serial controller. This makes the BACnet data available in the ASCII network. Up to 600 nodes.
This gateway allows Modbus TCP/RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 3000 points
This KNX TP server gateway connects KNX devices to a BACnet IP & MS/TP network. This makes the KNX data available in the BACnet network. Up to 1200 nodes.
This BACnet IP & MS/TP client gateway connects KNX devices to a BACnet network. This makes the KNX data available in the BACnet network. Up to 600 nodes.
This DALI server gateway allows DALI and DALI-2 devices to communicate on a BACnet IP network. The gateway can handle 2 DALI channels with each 128 drivers/ballast and 16 DALI-2 sensors.
This Profinet gateway connects BACnet IP & MS/TP networks with Profinet. The gateway works as a translator between the two networks. For 1200 BACnet objects.
This gateway allows Modbus TCP/RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 100 points
Connect your Modbus TCP network to EtherNet/IP via the Universal Anybus Communicator ABC4011. This gateway performs intelligent protocol conversion and provides the Modbus data to the EtherNet/IP Master.