The Anybus Communicator ABC4090 common Ethernet is an industrial protocol gateway that allows you to seamlessly transfer data between EtherNet/IP, Modbus TCP, EtherCAT and PROFINET networks and a Profibus DP network
This gateway allows Modbus TCP/RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 600 points
This KNX TP server gateway connects KNX devices to a BACnet IP & MS/TP network. This makes the KNX data available in the BACnet network. Up to 250 nodes.
Connect your EtherCAT network to Prodibus DP via the new generation Universal Anybus Communicator ABC4021. This gateway performs intelligent protocol conversion and provides the EtherCAT data to the Profibus DP Master.
Anybus X Gateway Modbus-TCP master (client) Modbus-TCP slave (server). Integrate your Modbus/TCP network quickly and easily with another Modbus-TCP network.
Now connect your RS-232/422/485 device to Devicenet via the Anybus Communicator RS. This gateway performs an intelligent protocol conversion and offers the serial data to the Master PLC / Controller as easy-to-use I / O data.
This Modbus TCP & RTU server gateway allows Modbus devices to communicate on a Bacnet network. Up to 5 simultaneous Modbus TCP servers and up to 32 Modbus devices per RTU node (without repeater) and up to 255 in total. 3000 data points.
This DALI / Dali-2 to Modbus gateway allows DALI devices to communicate on a Modbus network. The gateway acts as a translator between the two networks. For up to 64 DALI devices.
This BACnet MS/TP or IP server gateway connects BACnet devices with an ASCII IP or serial controller. This makes the BACnet data available in the ASCII network. Up to 3000 nodes.
This gateway allows Modbus TCP & RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per node (RTU and TCP). Maximum 3000 points
This KNX TP server gateway connects KNX devices to a BACnet IP & MS/TP network. This makes the KNX data available in the BACnet network. Up to 600 nodes.
This BACnet IP & MS/TP client gateway connects KNX devices to a BACnet network. This makes the KNX data available in the BACnet network. Up to 100 nodes.
This gateway allows Modbus TCP/RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 1200 points
This gateway allows Modbus TCP/RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 600 points
This gateway allows Modbus TCP/RTU devices to communicate on a BACnet IP & or MS/TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 1200 points