Intesis

















Intesis M-Bus to Modbus gateway INMBSMEB1200000 - 120 devices

This M-Bus gateway allows 120 M-Bus devices to communicate on a Modbus network. The gateway works as a translator between the two networks.
Compare

€1.450,00

Information

Intesis IN702MEB0600000 gateway M-Bus, Modbus and digital meters to BACnet, KNX or Modbus – 60 devices

Integrate M-Bus devices, Modbus devices, and digital meters into a BACnet, KNX or Modbus system. Up to 60 M-Bus devices.
Compare

€1.277,00

Information

Intesis M-Bus to BACnet IP & MS/TP server gateway INBACMEB1200000 - 120 devices

This M-Bus gateway allows 120 M-Bus devices to communicate on a BACnet IP or BACnet MS/TP network.
Compare

€1.740,00

Information

Intesis OCPP to Modbus TCP & RTU Server Gateway INMBSOCP0010100 1 charger with 7 connections

Integrate OCPP 1.6-based electric vehicle charging stations with any Modbus RTU or TCP controller or connect the chargers to an external OCPP Central System (CS) and monitor them via Modbus.
Compare

€467,00

Information

Intesis Modbus TCP & RTU Master to BACnet IP & MS/TP Server IN7004852500000 - 250 points

This Modbus TCP & RTU server gateway allows Modbus devices to communicate on a Bacnet network. Up to 5 simultaneous Modbus TCP servers and up to 32 Modbus devices per RTU node (without repeater), up to 255 in total. 250 data points.
Compare

€937,00

Information

Intesis Modbus to KNX gateway IN701KNX3K00000 - 3000 points

This gateway allows Modbus TCP/RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per Node (RTU and TCP). Maximum 3000 points
Compare

€2.603,00

Information

Intesis Modbus to KNX gateway IN701KNX6000000 - 600 data points

This gateway allows Modbus TCP/RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and up to 255 Modbus devices per node (RTU and TCP). Up to 600 data points.
Compare

€1.264,00

Information

Intesis BACnet IP & MS/TP Client to KNX TP gateway, IN701KNX3K00000 - 3000 data punten

This BACnet IP & MS/TP client gateway connects KNX devices to a BACnet network. This makes the KNX data available in the BACnet network. Up to 3000 nodes.
Compare

€2.603,00

Information

Intesis M-Bus to Modbus gateway INMBSMEB0500100 - 50 devices

This M-Bus gateway allows 50 M-Bus devices to communicate on a Modbus network. The gateway acts as a translator between the two networks.
Compare

€650,00

Information

Intesis BACnet to ASCII gateway, IN7004851K20000 - 1200 nodes

This BACnet MS/TP or IP server gateway connects BACnet devices with an ASCII IP or serial controller. This makes the BACnet data available in the ASCII network. Up to 1200 nodes.
Compare

€1.830,00

Information

Intesis BACnet to ASCII gateway, IN7004852500000- 250 nodes

This BACnet MS/TP or IP server gateway connects BACnet devices with an ASCII IP or serial controller. This makes the BACnet data available in the ASCII network. Up to 250 nodes.
Compare

€937,00

Information

Intesis Modbus TCP & RTU to KNX gateway IN701KNX2500000 - 250 points

This gateway allows Modbus TCP & RTU devices to communicate on a KNX TP network. Up to 5 Modbus TCP nodes/devices and to 255 Modbus Devices per node (RTU and TCP). Maximum 250 points
Compare

€992,00

Information